*DECK THMCCD
REAL FUNCTION THMGCD(TEMP)
*
*-----------------------------------------------------------------------
*
*Purpose:
* Compute the product of the heat capacity of cladding (in J/Kg/K) times
* its density (in Kg/m^3).
*
*Copyright:
* Copyright (C) 2013 Ecole Polytechnique de Montreal.
*
*Author(s):
* P. Gallet
*
*Parameters: input
* TEMP cladding temperature in Kelvin.
*
*Parameters: output
* THMGCD product of the heat capacity of the cladding times its density
* (in J/K/m^3).
*
*-----------------------------------------------------------------------
*
IMPLICIT NONE
*----
* SUBROUTINE ARGUMENTS
*----
REAL TEMP
*----
* LOCAL VARIABLES
* CP: cladding heat capacity in J/Kg/K
* RO: cladding density with zero porosity in kg/m^3
*----
REAL CP,RO,DKELV,T0,T1,T2
PARAMETER (DKELV=273.15,T0=1090.0,T1=1169.0,T2=1243.0)
*
* calculation of the density of the cladding with the value of the
* temperature
RO=6690.0-0.1855*TEMP
* calculation of the heat capacity of the cladding in J/kg/K
IF(TEMP.LE.T0) THEN
* for : T<1090.0
CP=226.7+0.2066*TEMP-0.6492E-04*TEMP**2.0
ELSE IF(TEMP.LE.T1) THEN
* for : 1090<=T<1169.0
CP=6.94*TEMP-7189.0
ELSE IF(TEMP.LE.T2) THEN
* for : 1169<=T<1243.0
CP=9312.9-7.177*TEMP
ELSE
* for T>=1243.0
CP=356.0
ENDIF
* calculation of internal energy of the cladding in J/m^3/K
THMGCD=RO*CP
RETURN
END
|