*DECK DETPLAT
SUBROUTINE DETPLAT(DT,RESPON,REF,KC,PDD,REGUL,PDF,PDT,NDDG,
+ AP,BP)
*
*-----------------------------------------------------------------------
*
*Purpose:
* Computes platinum detector reading with delay time consideration
* and normalized to a reference value.
*
*Copyright:
* Copyright (C) 2010 Ecole Polytechnique de Montreal.
*
*Author(s):
* E. Varin
*
*Parameters:
* DT
* RESPON
* REF
* KC
* PDD
* REGUL
* PDF
* PDT
* NDDG
* AP
* BP
*
*-----------------------------------------------------------------------
*
INTEGER NDDG,I
REAL RESPON,REF,DT
REAL AEP,AP(NDDG),BP(NDDG),PDT(NDDG),PDF(NDDG+1),PDD(NDDG),PDO
LOGICAL REGUL
*
* FLUX AT DETECTOR SITE
* ---------------------
IF ( KC.EQ.0) THEN
* REFERENCE CALCULATION
*
PDO = RESPON
IF (REGUL) THEN
CALL DETFIL(PDO,RESPON,RESPON,25.,DT,1)
ENDIF
IF (PDO.EQ.0.0) THEN
PDO = 1.
WRITE(6,*)'===> DETECTOR HAS AN INITIAL ZERO VALUE <==='
ENDIF
REF = PDO
ENDIF
*
* NORMALIZATION TO REFERENCE VALUE
*
RESPON = RESPON/REF
*
DO 10 I = 1 , NDDG
*
AEP = DT*PDT(I)
AP(I) = 1.0
*
IF (AEP.GT.20.0) THEN
AEP = 20.0
ENDIF
IF (AEP.GT.1.0E-6) THEN
AP(I) = EXP ( -AEP )
ENDIF
BP(I) = 1.0 - AP(I)
*
10 CONTINUE
*
IF (KC.EQ.0) THEN
*
* INITIALISATION AT REFERENCE CALCULATION
* ---------------------------------------
*
DO 20 I = 1 , NDDG
PDD(I) = PDF(I+1) * RESPON
20 CONTINUE
ENDIF
*
* CALCULATION OF DETECTOR RESPONSE
* --------------------------------
*
PDO = 0.0
PDO = PDF(1)*RESPON
DO 30 I = 1 , NDDG
PDD(I) = AP(I)*PDD(I) + BP(I)*PDF(I+1)*RESPON
PDO = PDO + PDD(I)
30 CONTINUE
*
RESPON = PDO
*
RETURN
END
|