*---- * TEST CASE TCM15 * VVER Assembly of central water hole with 6 identical fuel cells * NXT flux * Coarse mesh *---- MODULE MAC: GEO: NXT: ASM: FLU: DELETE: END: ; LINKED_LIST MACRO GEOMF TRACK PIJMAT FLUX ; SEQ_BINARY TRACK_LGT ; PROCEDURE assertS ; *---- * Macroscopic XS *---- MACRO := MAC: :: NGRO 2 NMIX 4 NIFI 1 READ INPUT MIX 1 TOTAL 2.60458171E-1 3.77224326E-1 SCAT 2 2 5.98954648E-5 2.49342978E-1 2 2 3.77127469E-1 1.11155845E-2 MIX 2 TOTAL 1.49818063E-1 1.59792125E-1 SCAT 2 2 7.40572286E-5 1.47693634E-1 2 2 1.57371104E-1 1.30506000E-3 MIX 3 TOTAL 3.22798014E-1 3.81341100E-1 NUSIGF 5.46564534E-3 7.17375278E-2 CHI 1.0 0.0 SCAT 2 2 3.13575147E-4 3.11233580E-1 2 2 3.24143648E-1 2.19577667E-3 MIX 4 TOTAL 2.60458171E-1 3.77224326E-1 SCAT 2 2 5.98954648E-5 2.49342978E-1 2 2 3.77127469E-1 1.11155845E-2 ; *---- * Geometries NXT *---- GEOMF := GEO: :: HEX 7 EDIT 2 HBC COMPLETE REFL CELL CT CFI CFI CFI CFI CFI CFI ::: CT := GEO: HEXTCEL 2 1 SIDE 0.736121593 SPLITR 3 1 MIX 1 2 1 RADIUS 0.0 0.386 0.445 ; ::: CFI := GEO: HEXTCEL 2 1 SIDE 0.736121593 SPLITR 3 1 MIX 3 2 1 RADIUS 0.0 0.386 0.445 ; ; *---- * Transport calculation * Flux calculation *---- TRACK TRACK_LGT := NXT: GEOMF :: EDIT 3 TITL 'VVER-NXT: Flux' TISO 50 100.0 ; PIJMAT := ASM: MACRO TRACK TRACK_LGT :: EDIT 1 ; FLUX := FLU: PIJMAT MACRO TRACK :: EDIT 1 TYPE K ; assertS FLUX :: 'K-EFFECTIVE' 1 1.055674 ; TRACK TRACK_LGT GEOMF := DELETE: TRACK TRACK_LGT GEOMF ; PIJMAT FLUX := DELETE: PIJMAT FLUX ; MACRO := DELETE: MACRO ; ECHO "test TCM15 completed" ; END: ; QUIT "LIST" .