*---- * TEST CASE UOX_5x5_TG6_sym8_multiDom_rt2 * SIMPLE 5 X 5 PWR ASSEMBLY WITH TRIVAC * Input cross section data from Apex *---- * Define STRUCTURES and MODULES used *---- LINKED_LIST ASSMB TRACK MACRO SYS FLUX ; HDF5_FILE UOX_5x5 :: FILE './UOX_5x5_TG6_sym8_multiDom.h5' ; MODULE GEO: HUTL: SPH: TRIVAT: TRIVAA: FLUD: END: ; REAL B2 ; PROCEDURE assertS ; REAL side1 := 1.26 ; REAL side2 := side1 1.26 + ; REAL side3 := side2 1.26 + ; ASSMB := GEO: :: CAR2D 3 3 (*ASSEMBLY 5 X 5*) X- DIAG X+ REFL Y- SYME Y+ DIAG MESHX 0.0 <> <> <> MIX 1 2 4 3 5 6 ; TRACK := TRIVAT: ASSMB :: TITLE 'SIMPLE 5x5 FUEL ASSEMBLY' EDIT 0 MAXR 3000 DUAL 3 1 SPN 5 SCAT 1 ; HUTL: UOX_5x5 :: DIR GREP '/calc 1/miscellaneous/B2' 1 >>B2<< ; ECHO 'buckling B2=' B2 ; UOX_5x5 := SPH: UOX_5x5 TRACK :: EDIT 6 STEP AT 1 EQUI 'equivalence_SP3_P0c_rt2' ; MACRO := SPH: UOX_5x5 :: EDIT 3 STEP AT 1 MACRO SPRD EQUI 'equivalence_SP3_P0c_rt2' LEAK <> ; SYS := TRIVAA: MACRO TRACK ; FLUX := FLUD: SYS TRACK :: EDIT 1 ADI 4 ACCE 5 3 ; assertS FLUX :: 'K-EFFECTIVE' 1 0.9982139 ; ECHO "UOX_5x5_TG6_sym8_multiDom_rt2 completed" ; END: ;